Design of Steel Structures (2180610) MCQs

MCQs of Design of Industrial Building

Showing 31 to 37 out of 37 Questions
31.
Additional Impact load on electrically operated crane for horizontal forces transverse to rails is __________
(a) 25 % of the weight of the crab and the weight lifted by cranes.
(b) 10 % of maximum static wheel load.
(c) 5 % of the weight of the crab and the weight lifted by cranes.
(d) 10 % of the weight of the crab and the weight lifted by cranes.
Answer:

Option (d)

32.
Additional Impact load on overhead cranes for Horizontal forces along the rails________
(a) 5 % of all static wheel load.
(b) 5 % of maximum static wheel load.
(c) 10 % of the weight of the crab and the weight lifted by cranes.
(d) 5 % of the weight of the crab and the weight lifted by cranes.
Answer:

Option (a)

33.
Surge load is generated by_________
(a) Vertical load generated by weight of crane.
(b) Braking or acceleration of crane.
(c) Braking or acceleration of trolly.
(d) None of Above.
Answer:

Option (c)

34.
Nature of Surge load on Gantry girder is______
(a) Lateral load
(b) Gravity load
(c) Longitudinal load
(d) Dynamic load
Answer:

Option (a)

35.
Drag load on Gantry girder is generated by_________
(a) Vertical load generated by weight of crane and trolly.
(b) Braking or acceleration of crane.
(c) Braking or acceleration of trolly.
(d) All of above.
Answer:

Option (b)

36.
Nature of Drag load on Gantry girder is______
(a) Lateral load
(b) Area load
(c) Longitudinal load
(d) Gravity load
Answer:

Option (c)

37.
The surge load is assumed to be resisted by the ___________
(a) whole cross section.
(b) compression flange alone.
(c) compression and tension flanges.
(d) cross section above neutral axis.
Answer:

Option (b)

Showing 31 to 37 out of 37 Questions